<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.1d1" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher">Applied Information Aspects of Medicine (Prikladnye informacionnye aspekty mediciny)</journal-id><journal-title-group><journal-title>Applied Information Aspects of Medicine (Prikladnye informacionnye aspekty mediciny)</journal-title></journal-title-group><issn publication-format="electronic">2070-9277</issn><publisher><publisher-name>Voronezh State Medical University named after N.N. Burdenko - The State Budgetary Institution of Higher Professional Education «Voronezh State Medical University named after N.N. Burdenko» of the Ministry of Public Health of the Russian</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">11643</article-id><article-id pub-id-type="doi">10.18499/2070-9277-2026-29-3-44-53</article-id><article-categories><subj-group subj-group-type="heading"><subject>Science Report</subject></subj-group></article-categories><title-group><article-title>Comparative assessment of the accuracy of impressions obtained using different impression weights and intraoral scanning data</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Kalinovskiy</surname><given-names>Sergei</given-names></name><email>Kalinovskiysi@yahoo.com</email><uri content-type="orcid">https://orcid.org/0000-0002-6222-3053</uri><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Sevbitov</surname><given-names>Andrey</given-names></name><email>avsevbitov@mail.ru</email><uri content-type="orcid">https://orcid.org/0000-0002-8247-3586</uri><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Oleynikov</surname><given-names>Alexander</given-names></name><email>bandprod@yandex.ru</email><uri content-type="orcid">https://orcid.org/0000-0002-2245-1051</uri><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Resh</surname><given-names>Efim</given-names></name><email>r.efim1910@gmail.com</email><uri content-type="orcid">https://orcid.org/0009-0000-4779-5865</uri><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Shmoilov</surname><given-names>Andrey</given-names></name><email>shmoilovae@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Zhukovets</surname><given-names>Dmitry</given-names></name><email>jukovets.dmitry@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Gluhova</surname><given-names>Elena Alexandrovna</given-names></name><email>gluh.e@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff id="aff-1"></aff><aff id="aff-2">Ryazan State Medical University</aff><pub-date date-type="epub" iso-8601-date="2026-09-30" publication-format="electronic"><day>30</day><month>09</month><year>2026</year></pub-date><volume>29</volume><issue>3</issue><fpage>44</fpage><lpage>53</lpage><history><pub-date date-type="received" iso-8601-date="2026-06-17"><day>17</day><month>06</month><year>2026</year></pub-date></history><permissions><copyright-statement>Copyright © 2026, Applied Information Aspects of Medicine (Prikladnye informacionnye aspekty mediciny)</copyright-statement><copyright-year>2026</copyright-year></permissions><abstract>&lt;p&gt;Relevance: despite the availability of publications on the accuracy of various impression materials, a comparative assessment of traditional analog impressions and the intraoral scanning method in terms of direct reproduction of the anatomy of the dentition remains insufficiently represented in the literature. The purpose of this study is to compare the accuracy of reproduction of anatomical details of dental rows using traditional impression masses (alginate, A-silicone and C-silicone) in comparison with intraoral scanning data. Materials and methods: the study included 30 patients with intact dentition. Each patient received impressions of the upper jaw with alginate, A-silicone and C-silicone masses, and also underwent intraoral scanning with the 3Shape TRIOS 3 Basic system (3Shape A/S, Denmark). Monolithic gypsum models made of Elite Rock class IV gypsum (Zhermack SpA, Italy) were made from the impressions, which were subsequently digitized with a Ceramill Map 400 laboratory scanner (Amann Girrbach AG, Austria). The analysis of the reproduction accuracy of teeth 1.6 and 2.1 was performed in the Geomagic Control X program (3D Systems, USA) by superposition with respect to intraoral scanning data (etalon). Results: the highest accuracy among analog methods was demonstrated by A-silicone impressions: the deviation was 0.00320.0004 mm for tooth 1.6 and 0.00300.0003 mm for tooth 2.1. For alginate impressions, the deviation was 0.00380.0005 mm and 0.00360.0004 mm, for C-silicone  0.00550.0006 mm and 0.00530.0006 mm accordingly. Intergroup differences are statistically significant (p0.001). Conclusion: A-silicone materials provide accuracy as close as possible to intraoral scanning. Alginate impressions give clinically acceptable results, while C-silicones show the greatest deviations.&lt;/p&gt;</abstract><kwd-group xml:lang="en"><kwd>orthopedic dentistry</kwd><kwd>impression materials</kwd><kwd>intraoral scanning</kwd><kwd>digital impressions</kwd><kwd>accuracy of impressions</kwd><kwd>A-silicone</kwd><kwd>C-silicone</kwd><kwd>alginate.</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>ортопедическая стоматология</kwd><kwd>оттискные материалы</kwd><kwd>интраоральное сканирование</kwd><kwd>цифровые оттиски</kwd><kwd>точность оттисков</kwd><kwd>А-силикон</kwd><kwd>С-силикон</kwd><kwd>альгинат.</kwd></kwd-group></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Калиновский С.И., Севбитов А.В., Шмойлов А.Е., Олейников А.А., Реш Е.Р., Огарева А.Р. Сравнительная оценка прецизионности гипсовых моделей челюстей, изготовленных по различной технологии с использованием оттискных масс: неконтролируемое клинико-лабораторное исследование // Российский стоматологический журнал. - 2026. - Т. 30. - №1. - C. 29-38. DOI: 10.17816/dent701755</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Вокулова Ю. А., Жулев Е. Н. Результаты изучения цифровых изображений базисов полных съёмных протезов, изготовленных с помощью 3D-печати и традиционных технологий // Клиническая стоматология 2021. Т. 97, № 1. С. 131-135. DOI: 10.37988/1811-153X-2021-1-131</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Kahya Karaca Ş., Akca K. Comparison of conventional and digital impression approaches for edentulous maxilla: a clinical study // BMC Oral Health. 2024. Vol. 24, Article 524. DOI: 10.1186/S12903-024-05151-3.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Янишен И. В., Герман С. А. Оценка физико-механических свойств А-силиконовых эластических конструкционных материалов: сравнительный анализ // МЦНП «Новая наука», 2021. C. 112-118. ISBN 978-5-00174-287-4.</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Ячменева Л. А., Кривцова А. С. Сравнительная характеристика эффективности силиконовых оттискных материалов // Innova. 2018. Т. 10, № 1. С. 15-17. DOI:10.21626/innova/2018.1/03</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Полонейчик Н.М., Петражицкая Г.В. Методы изготовления гипсовых моделей: учебно-методическое пособие // Минск: БГМУ, 2020. 28 с., ISBN 978-985-21-0520-0</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Marco Cicciù, Luca Fiorillo, Cesare D'Amico et. al 3D Digital Impression Systems Compared with Traditional Techniques in Dentistry: A Recent Data Systematic Review // Materials Basel. 2020. Vol. 8, № 13. DOI:10.3390/ma13081982.</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>Беляев М. В. Возможности портативных триангуляционных 3D-сканеров в трасологических исследованиях // Вестник экономической безопасности. 2022. № 3. C. 41-45. DOI: 10.24412/2414-3995-2022-3-41-45</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>Бородина И. Д., Григорьянц Л. С., Гаджиева М. А., Апресян С. С., Батов Р. В., Степанов А. Г., Апресян С. В. Сравнительная оценка точности отображения зубной дуги при помощи современных интраоральных 3D-сканеров // Российский стоматологический журнал. 2020. Т. 24, № 6. C. 347-352. DOI: 10.18821/1728-2802-2020-24-6-347-35</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>Бордин Д. С., Машарова А. А., Дроздов В. Н., Фирсова Л. Д., Кожурина Т. С. Диагностическое значение альгинатного теста при гастроэзофагеальной рефлюксной болезни // Экспериментальная и клиническая гастроэнтерология. 2019. № 4. C. 13-19. DOI: 10.31146/1682-8658-ecg-164-4-13-19</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>Нагибина Л.А., Чаусова Ж.В., Матвеев С.В. др. Исследование экспансионной ошибки на начальных этапах ортопедического лечения // Медико-фармацевтический журнал пульс. 2019. Т. 10, № 5. C. 171, DOI: 10.26787/nydha-2686-6838-2019-21-8-53-58</mixed-citation></ref><ref id="B12"><label>12.</label><mixed-citation>Вахобов А.С. Повышение качества стоматологического лечения с использованием мобильных 3D-методов // Теория и практика современной науки. 2021. Т. 68, № 2. С. 25-30, EDN: FSQDOL</mixed-citation></ref><ref id="B13"><label>13.</label><mixed-citation>Набиуллина Г. И., Фазылова Д. И., Зенитова Л. А. Оттискные материалы для стоматологии (обзорная статья) // Вестник технологического университета. 2017. Т. 20, № 14. С. 46-50, EDN: ZDWPJF</mixed-citation></ref></ref-list></back></article>
