<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.1d1" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher">Applied Information Aspects of Medicine (Prikladnye informacionnye aspekty mediciny)</journal-id><journal-title-group><journal-title>Applied Information Aspects of Medicine (Prikladnye informacionnye aspekty mediciny)</journal-title></journal-title-group><issn publication-format="electronic">2070-9277</issn><publisher><publisher-name>Voronezh State Medical University named after N.N. Burdenko - The State Budgetary Institution of Higher Professional Education «Voronezh State Medical University named after N.N. Burdenko» of the Ministry of Public Health of the Russian</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">10994</article-id><article-id pub-id-type="doi">10.18499/2070-9277-2025-28-3-20-29</article-id><article-categories><subj-group subj-group-type="heading"><subject></subject></subj-group></article-categories><title-group><article-title>Comparative Characteristics of Standard and Individual Impression Transfers in Implantology: Development of a Digital Library and Clinical Verification</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Lapina</surname><given-names>Natalya Victorovna</given-names></name><bio>&lt;p&gt;MD, Professor, Head of the Department of Orthopedic Dentistry, Head of the Department of Dentistry&lt;/p&gt;</bio><email>kgma74@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Boglay</surname><given-names>Nikolay Nikolaevich</given-names></name><bio>&lt;p&gt;Postgraduate student of the Department of Orthopedic Dentistry&lt;/p&gt;</bio><email>boglayn@bk.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Seferyan</surname><given-names>Karina Gevorkovna</given-names></name><bio>&lt;p&gt;PhD, Associate Professor of the Department of Orthopedic Dentistry&lt;/p&gt;</bio><email>KGSefer@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Selyavko</surname><given-names>Elina Alekseevna</given-names></name><bio>&lt;p&gt;student of the Faculty of Dentistry&lt;/p&gt;</bio><email>elinkagerut@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff id="aff-1">KubSMU Federal State Budgetary Educational Institution of the Ministry of Health of Russia</aff><pub-date date-type="epub" iso-8601-date="2025-11-09" publication-format="electronic"><day>09</day><month>11</month><year>2025</year></pub-date><volume>28</volume><issue>3</issue><fpage>20</fpage><lpage>29</lpage><history><pub-date date-type="received" iso-8601-date="2025-10-01"><day>01</day><month>10</month><year>2025</year></pub-date></history><permissions><copyright-statement>Copyright © 2025, Applied Information Aspects of Medicine (Prikladnye informacionnye aspekty mediciny)</copyright-statement><copyright-year>2025</copyright-year></permissions><abstract>&lt;p&gt;Modern implant dentistry is focused on improving the accuracy of transferring the three-dimensional position of dental implants, as this parameter largely determines the functional reliability and biomechanical stability of prosthetic constructions. One of the key factors influencing treatment outcomes is the choice of impression transfers. Analysis has shown that standard transfers, despite their universality and broad compatibility, provide acceptable results only in uncomplicated anatomical situations, whereas in complex clinical conditions the risk of reduced accuracy increases. In contrast, customized designs created using CAD/CAM technologies through additive manufacturing or high-precision milling demonstrate higher reproducibility and the ability to adapt to the specific patient. In this study, a comparison was carried out between the structural and functional characteristics of both types of transfers, and a digital library of individualized models was developed and integrated into CAD/CAM systems. Clinical testing confirmed the high accuracy and ease of use of customized designs, supporting the feasibility of their widespread implementation. The findings substantiate the advisability of employing digital libraries not only in clinical practice but also in educational programs, forming the basis for selecting the optimal transfer strategy depending on anatomical features and available technological resources.&lt;/p&gt;</abstract><kwd-group xml:lang="en"><kwd>dental implantation</kwd><kwd>impression coping</kwd><kwd>customized coping</kwd><kwd>standard coping</kwd><kwd>CAD/CAM technologies</kwd><kwd>3D printing</kwd><kwd>impression accuracy</kwd><kwd>prosthetic dentistry.</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>дентальная имплантация</kwd><kwd>слепочный трансфер</kwd><kwd>индивидуальный трансфер</kwd><kwd>стандартный трансфер</kwd><kwd>CAD/CAM-технологии</kwd><kwd>3D-печать</kwd><kwd>точность оттиска</kwd><kwd>ортопедическая стоматология.</kwd></kwd-group></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>1. Koshelev K.A., Belousov N.N., Algoeva A.E., Bulanov V.I., Gerasimov A.M. Methodology for creating a digital library of individual impression copings for implant-supported restorations. Stomatology. 2022;101(5):142–147. DOI: 10.17116/stomat202210105142.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>2. Tyncherov R.R., Kalbaev A.A. Application of CAD/CAM technologies in the fabrication of individual impression copings. Stomatology. 2023;102(3):163–168. DOI: 10.17116/stomat202310203163.</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>3. Rozov R.A., Trezubov V.N., Pozzi A. Modern approaches to the individualization of copings in implant prosthodontics. Stomatology. 2018;97(2):50–56. DOI: 10.17116/stomat201897250.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>4. Rozov R.A., Trezubov V.N., Spitsyna O.B., Bystrova Yu.A. Influence of the design of individual copings on the accuracy of implant positioning. Stomatology. 2021;100(4):32–39. DOI: 10.17116/stomat202110004132.</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>5. Zorina Yu.Yu., Oreshaka O.V., Ganisik A.V. Study of the effect of the occlusal surface of artificial crowns on stress distribution in implant prosthetics. Stomatology. 2022;101(3):32–39. DOI: 10.17116/stomat202210103032.</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>6. Ryakhovsky A.N. Determination of the magnitude of occlusal supracontacts during virtual merging of scans in habitual occlusion. Stomatology. [Year, volume, issue, pages to be specified].</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>7. Chkhikhvadze V.D. Optimization of the design of impression trays for extended implant-supported prostheses. Stomatology. 2018;97(3):32–39.</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>8. Ryakhovsky A.N., Muradov M.A., Erokhin V.A. Study of the accuracy of virtual repositioning of the mandible. Stomatology. 2022;101(4):53–60.</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>9. Rozov R.A., Trezubov V.N., Urakov A.L. Individual digital reconstruction of the biomechanics of the masticatory and speech apparatus in implant-supported prosthetics of patients with complete edentulism. Russian Journal of Biomechanics. No. 3, 2022, pp. 10–115.</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>10. Rozov R.A., Trezubov V.N., Pozzi A. Implant prosthetics with extended monolithic zirconia constructions using digital modeling of occlusal surfaces. Clinical Medicine. DOI: 10.26442/2218-7332_2018.3.41-48.</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>11. Zhulev E.N., Vokulova Yu.A. Study of the dimensional accuracy of the internal fit of lithium disilicate crowns fabricated using conventional and digital technologies. Actual Problems of Medicine. 2020; Vol. 43, No. 2: 237–248.</mixed-citation></ref><ref id="B12"><label>12.</label><mixed-citation>12. Arutyunov S.D., Grachev D.I., Bagdasaryan G.G., Nikitin V.N., Maksimova N.V., Nikitin A.D. Mathematical modeling of the biomechanical behavior of a removable denture base under typical masticatory loads. Russian Journal of Biomechanics. 2020; Vol. 24, No. 4: 491–504.</mixed-citation></ref><ref id="B13"><label>13.</label><mixed-citation>13. Polushkina N.A., Vechyorkina Zh.V., Chirkova N.V. The effect of thermoplastic polymer on the prosthetic bed tissues in patients with chronic generalized periodontitis and partial edentulism. Applied Information Aspects of Medicine. 2022: 37–47.</mixed-citation></ref><ref id="B14"><label>14.</label><mixed-citation>14. Negmatova D.U., Zainiev S.S., Kamariddinzoda M.K. Possibilities of prosthetics supported by dental implants. Achievements of Science and Education. 2020; No. 6(60).</mixed-citation></ref><ref id="B15"><label>15.</label><mixed-citation>15. King E.M., McAllister K. Restoratively driven planning for implants in the posterior maxilla: Proposal of the Posterior Maxilla Prosthodontic Index (PMPI). British Dental Journal. 2023;235(9):-.DOI:10.1038/s41415-023-6440-2..</mixed-citation></ref><ref id="B16"><label>16.</label><mixed-citation>16. Gao Y., Chen H., Wang J. Digital occlusal contact analysis: comparison between virtual and clinical methods. Journal of Prosthetic Dentistry. 2021;126(5):671–678. DOI: 10.1016/j.prosdent.2020.03.028.</mixed-citation></ref><ref id="B17"><label>17.</label><mixed-citation>17. Kumar P., Singh V., Jain V. Integration of CAD/CAM technology in implant dentistry: the 4D planning approach. Clinical Oral Implants Research. 2020;31(8):755–763. DOI: 10.1111/clr.13623.</mixed-citation></ref><ref id="B18"><label>18.</label><mixed-citation>18. Lee S.J., Gallucci G.O. Accuracy of digital implant impressions: a systematic review. Journal of Prosthetic Dentistry. 2019;122(6):547–554. DOI: 10.1016/j.prosdent.2019.01.001.</mixed-citation></ref><ref id="B19"><label>19.</label><mixed-citation>19. Mora M.A., Chenin D.L., Arce R.M. Evaluation of customized impression copings for improved accuracy. International Journal of Oral &amp; Maxillofacial Implants. 2019;34(5):1125–1132. DOI: 10.11607/jomi.7456.</mixed-citation></ref><ref id="B20"><label>20.</label><mixed-citation>20. Rossi F., Menini M., Dellepiane E. Clinical validation of a fully digital workflow for implant-supported prostheses. Clinical Oral Investigations. 2021;25(2):651–660. DOI: 10.1007/s00784-020-03275-8.</mixed-citation></ref><ref id="B21"><label>21.</label><mixed-citation>21. Szabó Á.L., Matusovits D., Slyteen H., Lakatos É.I., Baráth Z. Biomechanical effects of different load cases with an implant-supported full bridge on four implants in an edentulous mandible: A three-dimensional finite element analysis (3D-FEA). Dentistry Journal. 2023;11(11):261. DOI:10.3390/dj11110261..</mixed-citation></ref><ref id="B22"><label>22.</label><mixed-citation>22. Rungsiyakull P., Sun C., Li Z., et al. Effects of bone type and occlusal loading pattern on remodeling of bone around a single implant-supported crown: Three-dimensional finite element analysis. Journal of Prosthodontics. 2023;32(10):e1–e12. DOI:10.1111/jopr.13679.</mixed-citation></ref><ref id="B23"><label>23.</label><mixed-citation>23. Tanaka M., Morita O., Hirano S. Accuracy of mandibular repositioning using CBCT and intraoral scanning. Journal of Prosthodontics. 2020;29(8):713–720. DOI: 10.1111/jopr.13204.</mixed-citation></ref><ref id="B24"><label>24.</label><mixed-citation>24. Paolo Baldissara 1, Brunilda Koci 2, Aion Mangino Messias 3, Roberto Meneghello 4, Francesco Ghelli 5, Maria Rosaria Gatto 6, Leonardo Ciocca 7. Assessment of impression material accuracy in complete-arch restorations on four implants. Journal of Prosthetic Dentistry,2021, P 763-771.</mixed-citation></ref><ref id="B25"><label>25.</label><mixed-citation>Abstract.</mixed-citation></ref></ref-list></back></article>
